The EN60-CX series outdoor control cabinet adopts an integrated design concept, which integrates energy storage inverters, combiner cabinets, outgoing cabinets, energy management systems, and other equipment in an ultra-high and compact manner. It is perfectly matched with EN60-CX-X outdoor battery cabinets to meet various scene requirements.
Product highlights: Prefabricated cabin design, reduces on-site wiring workload by 70%, eliminates the need for large cranes, and allows forklift installation.Exquisite
1800mm * 1055mm * 2295mmCompact
~2t, floor area reduced by 1/3,
Intelligent
Embedded edge computing module, EMS integration
Security
Shell design for collision prevention
Easy to install
Bottom confluence design for convenient installation of irregular layouts
Flexible
Unlimited parallel connection, maintenance outside the cabinet -
Model
EN60-CX-C-500
EN60-CX-C-630
DC Side Parameters
Maximum DC Power (kW)
550kW
693KW
Maximum Voltage Of DC Bus (V)
1000V
Maximum Vurrent On DC Side (A)
948A
1195A
Working Range Of DC Voltage (V)
550~1000V
Full Load Working Range (V)
580~850V
DC Voltage Ripple Coefficient (%)
<2%
Communication Parameters (Grid Connection)
Rated Power (KW) 500KW
500kW
630kW
Maximum Output Power (kW)
550kW
693kW
Rated Output Current
760A
957A
Maximum Output Current
912A
1148A
Communication Access Method
Three Phase Three Wire
Isolation Method
No Isolation
Reactive Power Range (kvar)
-500kvar~500kvar
-630kvar~630kvar
Rated Grid Voltage (V)
380V
Allow Grid Voltage (V)
-15% ~ 10% OR 323 V - 418V
Rated Grid Frequency (Hz)
50Hz/60Hz
Permissible Frequency Deviation (Hz)
±2Hz
Total Harmonic Distortion Rate Of Current (%)
<3%(Rated Power)
Power Factor
-1 ~ +1
Charge Discharge Conversion Time (ms)
<20ms
Communication Parameters (Off Grid)
Rated Output Voltage (V)
380V
Voltage Deviation
±3%
Voltage Imbalance (%)
<2%, Short-term<4%
Total Harmonic Distortion Rate Of Voltage (%)
<3% (Linear Load)
Rated Output Frequency (Hz)
50Hz/60Hz
Dynamic Voltage Transient Range (%)
<10%
Basic Parameters
Incoming Method
Bottom
Maximum Efficiency
99%
EMS
EN-3060-PANGU OS
Charging Interface
Integration
Noise (DB)
<80dB
Weight (kg)
2t
Dimensions (Width * Depth * Height) (mm)
1800*1055*2295
Protection Level
IP55
Cooling Method
Forced Air Cooling
Adaptation (Battery Cabinet)
EN60-CX-X Series Products